Underground Duct Dielectric Multi-Tube
12F-864F Single Sheath - Unarmored
Cable Construction Details:
Core: 12 to 864 optical fibers in a multi-tube structure for high-density transmission.
Buffer Tubes: Individual fiber protection for easy identification and splicing.
Multi-Tube Design: Provides excellent fiber management for underground duct installations.
Dielectric Construction: Non-metallic design prevents electrical interference.
Primary Sheath: Protects against moisture, chemicals, and physical stress.
Outer Sheath: Resists UV, moisture, and physical damage.
Rip Cord: Incorporated to open the sheath.
Special Features:
High Fiber Density: 12 to 864 fibers for high-capacity transmission.
Fiber Management: Multi-tube construction simplifies splicing and organization.
Electrical Safety: Dielectric design prevents interference.
Environmental Protection: Shields against moisture and physical stress.
Space-Efficient: Compact multi-tube structure ideal for underground ducts.
Cost-Effective: Unarmored design offers protection at a lower cost.
Compatible with Duct Installations, Pulled and Blown:
Standard Cross-Section of 864 Fibers:
12F-288F Single Sheath - Rodent Protected
Cable Construction Details:
Core: 12 to 288 optical fibers in a multi-tube structure for high-density transmission.
Buffer Tubes: Individual fiber protection for easy identification and splicing.
Multi-Tube Design: Enhanced fiber management for complex underground duct installations.
Rodent Protection: Specialized materials prevent damage from rodents.
Dielectric Construction: Non-metallic design resists electrical interference.
Primary Sheath: Protection against moisture, chemicals, and physical stress.
Outer Sheath: Resists UV, moisture, and physical damage.
Rip Cord: Incorporated to open the sheath.
Special Features:
High Fiber Density: 12 to 288 fibers for high-capacity transmission.
Rodent Protection: Safeguards against rodent damage in underground settings.
Fiber Management: Simplifies splicing with multi-tube construction.
Electrical Safety: Dielectric design prevents interference.
Environmental Protection: Shields from moisture and physical stress.
Space-Efficient: Compact design for efficient underground installation.
Durable: Rodent protection ensures long-term reliability.
Compatible with Duct Installations, Pulled and Blown:
Standard Cross-Section Layout for 96 Fibers:
12F-1152F Single Sheath - Micro Module - 2FRP
Cable Construction Details:
Core: 12 to 1152 optical fibers in micro modules for high-density transmission.
Micro Modules: Enhance fiber organization and simplify splicing.
Multi-Tube Design: Offers efficient fiber management for underground duct installations.
2FRP Reinforcement: Provides added mechanical strength and protection.
Dielectric Construction: Non-metallic design prevents electrical interference.
Primary Sheath: Protection against moisture, chemicals, and environmental factors.
Outer Sheath: Resists UV, moisture, and physical damage.
Rip Cord: Incorporated for easy stripping and access to fibers.
Special Features:
High Fiber Density: 12 to 1152 fibers in a micro module multi-tube design.
Improved Fiber Management: Simplified splicing and organization.
Mechanical Strength: 2FRP reinforcement ensures durability.
Electrical Safety: Dielectric construction prevents interference.
Environmental Protection: Shields from moisture and physical stress.
Space-Efficient: Compact design for underground ducts.
Durability: Built to withstand harsh underground conditions.
Universal Design:
Standard Cross-Section Layout for 144 Fibers:
6F-144F Single Sheath - Micro Module - 4FRP - ADSS
Cable Construction Details:
Core: 6 to 144 optical fibers in micro modules for high-density transmission.
Micro Modules: Organize fibers for easier handling and splicing.
Multi-Tube Design: Provides efficient fiber management for underground duct installations.
4FRP Reinforcement: Adds mechanical strength and durability.
ADSS Design: Self-supporting, reducing the need for additional metallic support.
Dielectric Construction: Non-metallic, preventing electrical interference.
Primary Sheath: Protection against moisture, chemicals, and environmental stress.
Outer Sheath: Resists UV, moisture, and physical damage.
Rip Cord: Incorporated for easy stripping and access to fibers.
Special Features
High Fiber Density: 6 to 144 fibers in a micro module multi-tube design.
Fiber Management: Simplified splicing and organization with micro modules.
Mechanical Strength: 4FRP reinforcement ensures durability.
Self-Supporting: ADSS design reduces reliance on metallic supports.
Electrical Safety: Dielectric construction prevents interference.
Environmental Protection: Guards against moisture and physical damage.
Durability: Enhanced strength for harsh underground conditions.
Space-Efficient: Compact multi-tube design for efficient underground installation.
Universal Design:
Standard Cross-Section Layout for 36 Fibers:
144F-1728F Single Sheath - Ribbon Type
Cable Construction Details:
Core: 144 to 1728 optical fibers in ribbon type configuration for high-density transmission.
Ribbon Type: Flat, high-density fiber organization for efficient splicing and access.
Multi-Tube Design: Groups ribbon fibers into multiple tubes for easier management and installation.
Dielectric Construction: Non-metallic, preventing electrical interference.
Primary Sheath: Protects against moisture, chemicals, and physical stress.
Outer Sheath: Resists UV, moisture, and physical damage for long-term durability.
Rip Cord: Incorporated to open the sheath.
Special Features
High Fiber Density: 144 to 1728 fibers in ribbon type for efficient transmission.
Improved Fiber Management: Easy access and splicing with ribbon type structure.
Electrical Safety: Dielectric design ensures immunity to interference.
Environmental Protection: Shields from moisture, chemicals, and physical damage.
Durability: Built for reliable use in underground ducts.
Space-Efficient: Ribbon type and multi-tube design maximize space.
Compatible with Duct Installations:
Standard Cross-Section Layout for 864 Fibers:
12F-288F Double Sheath - Rodent Protected
Cable Construction Details:
Core: 12 to 288 optical fibers in multi-tube structure for efficient transmission.
Multi-Tube Design: Organizes fibers for easy management and splicing.
Double Sheath: Two protective layers for enhanced durability.
Rodent Protection: Materials prevent rodent damage in underground environments.
Dielectric Construction: Non-metallic design to avoid electrical interference.
Primary & Outer Sheath: Protects fibers from moisture, chemicals, and physical stress.
Rip Cord: Incorporated for easy stripping and access to fibers.
Special Features:
High Fiber Capacity: 12 to 288 fibers in a multi-tube design.
Rodent Protection: Prevents rodent damage.
Improved Fiber Management: Easy splicing with multi-tube structure.
Electrical Safety: Dielectric construction prevents interference.
Environmental Protection: Double sheath for moisture and physical stress protection.
Durability: Ensures long-term reliability in harsh conditions.
Space-Efficient: Compact design ideal for underground ducts.
Compatible with Direct/Inside Duct Installations:
Standard Cross-Section Layout for 72 Fibers:
12F-144F Double Sheath - FRP Rod - Armored
Cable Construction Details:
Core: 12 to 144 optical fibers in multi-tube design for efficient transmission.
Multi-Tube Design: Organized fiber management and simplified splicing.
Double Sheath: Two layers for enhanced protection.
FRP Rod: Provides structural strength against mechanical stresses.
Armored: Steel or aluminum armor for protection against impact and external hazards.
Dielectric Construction: Non-metallic, preventing electrical interference.
Primary & Outer Sheath: Protects against moisture, chemicals, UV, and physical damage.
Special Features
High Fiber Capacity: 12 to 144 fibers in a multi-tube design.
Mechanical Strength: FRP rods and armored construction for added durability.
Rodent Protection: Armor prevents rodent damage.
Electrical Safety: Dielectric construction ensures no electrical interference.
Environmental Protection: Double sheath shields against moisture and physical stress.
Durability: Long-term reliability in harsh underground conditions.
Space-Efficient: Compact design for efficient use of duct space.
Compatible with High Pulling Force Installations:
Standard Cross-Section Layout for 72 Fibers:
12F-288F Double Sheath - Unarmored
Cable Construction Details:
Core: 12 to 288 optical fibers in multi-tube design.
Multi-Tube Design: Organized fiber management for easy splicing.
Double Sheath: Inner sheath for fiber protection and outer sheath for added durability.
Dielectric Construction: Non-metallic design prevents electrical interference.
Primary & Outer Sheath: Protects against moisture, chemicals, UV, and physical damage.
Rip Cord: Incorporated for easy stripping and access to fibers.
Special Features:
High Fiber Capacity: 12 to 288 fibers in multi-tube configuration.
Improved Fiber Management: Easy splicing with multi-tube design.
Electrical Safety: Dielectric design ensures immunity to interference.
Environmental Protection: Double sheath shields from moisture and physical stress.
Durability: Long-term reliability without armor.
Space-Efficient: Compact design for efficient duct use.
Compatible with Duct Installations, Pulled and Blown:
Standard Cross-Section Layout for 72 Fibers:
12F-388F Triple Sheath - FRP- Armored
Cable Construction Details:
Core: 12 to 388 optical fibers in multi-tube design.
Multi-Tube Design: Organized fiber management for easy splicing.
Triple Sheath: Three-layer protection—inner, middle, and outer sheaths for durability.
FRP Rods: Provide structural strength against mechanical stress.
Armored: Steel or aluminum armor offers protection against impact and external hazards.
Dielectric Construction: Non-metallic design prevents electrical interference.
Primary & Outer Sheath: Protects from moisture, chemicals, UV, and physical damage.
Rip Cord: Incorporated for easy stripping and access to fibers.
Special Features:
High Fiber Capacity: 12 to 388 fibers in multi-tube design.
Robust Protection: Triple sheath and FRP rods for mechanical and environmental durability.
Rodent & Environmental Protection: Armor resists rodent damage and harsh conditions.
Electrical Safety: Dielectric design prevents interference.
Durability: Reliable in underground ducts with protection from moisture and stress.
Space-Efficient: Optimized multi-tube design for duct usage.
Compatible with Duct/Direct Buried Installations:
Standard Cross-Section Layout for 144 Fibers:
Connect